Product Family
Workstation monitor WS Aware
Properties:
- "Big Brother" monitoring function detects users who are not correctly grounded
 - Extremely low voltage (25mV CA) for permanent monitoring of voltage and resistance of the twin conductor wrist straps
 - Monitoring of grounding parameters according to ANSI 6.1 and ANSI/ESD S20.20
 - EMI monitoring of ground connections
 - RJ45 port for data transfer to the computer
 
    Wrist monitor
| Ground connection: | 1 MOhm per wrist strap connector | 
| Wrist connections: | 2 x Remote Terminals (1 Operator, 1 visitor) | 
| Test voltage to the body | 0.025 V (25 mV) | 
| Body bleeder resistance alarm level: | 10 MOhm default*. | 
| Body voltage alarm level: | +/-2.5 V default*. | 
 
Ground monitor
| Hard ground terminal (tools, machine): | 2 connections | 
| Dissipative surfaces: | 2 connections | 
| Alarm for hard grounding*: | 10 Ohm default | 
| Alarm for dissipative grounding*: | 1 GOhm default | 
 Imposed voltage  | |
| Hard connection: | < 0.075 V open circuit | 
| Dissipative surfaces: | < 0.4 V open circuit | 
| Power consumption: | < 150 mA | 
| Dimensions: | 81 mm x 57 mm x 33 mm | 
| Weight (approx.): | 120 g | 
* These parameters are either locally settable in the control panel or through a plant monitoring system. Default values are used if there is no other specification.
Article image
                    Article description
                    ESD
                    
                                                                                                    
                            
                            
                            Width  
                                                                                
                            
                            
                            Height 
                                                                                
                            
                            
                            Length  
                                                                                
                            
                            
                            Recommended calibration interval
                                            
                    Price
                    Compare
                                    81 mm
                                                            
                                
                                
                                32 mm
                                                            
                                
                                
                                57 mm
                                                            
                                
                                
                                12 months bzw. according to test equipment list
                            
                            			
                            			
                        81 mm
                                                            
                                
                                
                                32 mm
                                                            
                                
                                
                                57 mm
                                                            
                                
                                
                                12 months bzw. according to test equipment list
                            
                            			
                            			
                        
	
					
							
					
							
					
							
					
							
						
						
						
						
						
						
						
						
			