EPA requirements according to DIN EN 61340-5-1
Work in accordance with standards

EPA requirements according to DIN EN 61340-5-1

ESD control
element
Product qualification a
Compliance verification b
Test procedure
Limits c
Based on testing procedures
Limits c
Work surfaces,
storage shelves
and transport
trolleys g
IEC 61340-2-3
Rgp < 1 x 109
Rp-p < 1 x 109
IEC 61340-2-3
Rg < 1 x 109
Wrist strap
connection point
-
-
-
Rg < 5 x 106
Flooring
IEC 61340-4-1 d,e
Rgp < 1 x 109
IEC 61340-4-1
Rg < 5 x 109
Ionization
IEC 61340-4-7
Decay (1000 V to 100 V
and
-1000 V to -100 V) < 20 s
Offset voltage < +/- 35 V
IEC 61340-4-7
Decay (1000 V to 100 V
and
-1000 V to -100 V) < 20 s
Offset voltage < +/- 35 V
Seating
IEC 61340-2-3 (measurement of resistance
to groundable point)
Rgp < 1 x 109
IEC 61340-4-9
Rg < 1 x 1011
EPA-clothing
IEC 61340-4-9
Rp-p < 1 x 1011
IEC 61340-4-9
Rp-p < 1 x 1011
Groundable
EPA clothing
IEC 61340-4-9
Rgp < 1 x 109
IEC 61340-4-9
Rgp < 1 x 109

Legend to the table

a
For product qualification, the environmental conditions for the test should be (12 ± 3) % relative humidity and (23 ± 2) °C. Unless specified in the referenced IEC standards, the minimum ambient temperature conditioning time for product qualification should be 48 h.
b
The test methods in the compliance verification column refer only to the basic test method. The test methods are not expected to be fully followed
c
Symbols used in this table: Rp-p refers to point-to-point resistance, Rg corresponds to resistance to ground and Rgp refers to resistance to groundable point.
d
The maximum admissible test voltage for the measurement of ESD floor coverings to be used for an ESD program that complies with this standard is 100 V.
e
If a flooring is used to ground the personnel handling ESDS, reference is made to the system requirements in table 2.
f
In situations where damage from the Charged Device Model (CDM) must be considered, a lower threshold of the point-to-point resistance Rp-p of 1 x 104 Ω is recommended.
g
Working surfaces are defined as any surface on which an ESD-sensitive element is placed.

Latest posts in the category "ESD insights"

blog/kachel_newsletter_millionenschaden_260x125px.png

Costly consequences of improper handling of ESD protective clothing

Failure to comply with ESD clothing regulations can result in millions of dollars in damage. The human factor remains the most sensitive issue in ESD safety. Learn how component weakening can have more expensive consequences than destruction and how you can minimize risks with certified ESD training!

blog/kachel_esd_checkliste_260x125px.png

Checklist ESD Protective Measures

Protection against electrostatic discharge (ESD) is critical in industrial sectors such as electronics, semiconductor manufacturing, and others where sensitive electronic components are processed.
We offer you an overview with our checklist and essential questions.

blog/kachel_kennzeichnung_berufs_sicherheitsschuhe_260x125px.png

Marking of safety and occupational footwear

The labelling of occupational and safety footwear in Europe is regulated by EU Directive 89/686/EEC and the standard EN ISO 20345:2011 (for safety footwear) and EN ISO 20347:2012 (for occupational footwear).
These standards set out the minimum requirements for the construction, design and testing of footwear intended for occupational health and safety at work.

Latest posts from our blog

blog/blog_tt_cup_2026_teaser_260x125px.png

2026 Tiefental Cup: Team Spirit, Excitement, Runner-up

With total dedication, great team spirit, and plenty of positive energy, our team once again took second place at the 2026 Tiefental Cup. In a tournament that remained exciting right up to the last minute, we may not have won the trophy in the end, but we did send a strong message of unity and shared commitment.

blog/kachel_abschluss_ausbildung_2026_260x125px.jpg

We congratulate our apprentices on passing their exams

They did it! Our apprentices have successfully passed their IHK exams with honors and taken the next step toward their professional futures. We offer our heartfelt congratulations and are very proud of their achievements.

blog/kachel_newsletter_millionenschaden_260x125px.png

Costly consequences of improper handling of ESD protective clothing

Failure to comply with ESD clothing regulations can result in millions of dollars in damage. The human factor remains the most sensitive issue in ESD safety. Learn how component weakening can have more expensive consequences than destruction and how you can minimize risks with certified ESD training!