Requirements for personal grounding according to DIN EN 61340-5-1
Carrying out correct personal grounding

Requirements for personal grounding according to DIN EN 61340-5-1

ESD Control element
Product qualification
Verification of compliance
Test method
Thresholdsb
Based on test method
Thresholdsb
Wrist straps (straps
and grounding cable)
IEC 61340-4-6
R < 5 x 106
or user-defined threshold
See wrist strap system
Resistance of the
wrist strap
IEC 61340-4-6
Inside
Outside
-
<= 1 x 108
<= 1 x 107
-
Not applicable
Not applicable
Wrist strap systema
Not applicable
IEC 61340-4-6
Testing the electrical connection of
the wrist strap
R < 3,5 x 107
Footwear
IEC 61340-4-3c
R <= 1 x 108 e
See system Person/footwear
System
Person/footwear/floor
IEC 61340-4-5
Rg <= 1 x 109
and absolute value of
body voltage
< 100 V (average of the
5 highest peaks)
IEC 61340-5-1
Rg < 1 x 109 d,f
System
Person/footwear
Not applicable
-
Rgp < 1 x 108

Legend to the table

a
In situations where EPA clothing (according to IEC 61340-4-9) is used as part of the wrist strap grounding path, the resistance of the complete system should be including person, protective clothing and grounding cable should be < 3.5 x 107 Ω.
b
Symbols used in this table: Rg corresponds to resistance to ground and Rgp refers to resistance to groundable point.
c
For the product qualification of footwear according to IEC 61340-4-3, the environmental conditions for the test should be (12 ± 3) % relative humidity and (23 ± 2) °C.
d
A periodic test of the generated body voltage should be performed to verify that the voltage is less than 100 V.
e
The threshold of the resistance applies to the successive measurement of a single foot at a time, not both feet at the same time.
f
The required threshold of<1.0 x 109 Ω is the highest allowable value. The user should set an upper limit based on the resistance values measured for the product qualification of the footwear and floor system which ensure a maximum generated body voltage of 100 V, and use these resistance values for the verification of compliance.

Latest posts in the category "Knowledge"

blog/kachel_kennzeichnung_berufs_sicherheitsschuhe_260x125px.png

Marking of safety and occupational footwear

The labelling of occupational and safety footwear in Europe is regulated by EU Directive 89/686/EEC and the standard EN ISO 20345:2011 (for safety footwear) and EN ISO 20347:2012 (for occupational footwear).
These standards set out the minimum requirements for the construction, design and testing of footwear intended for occupational health and safety at work.

blog/dpv-blog_weller-MS-kachel_260x125px.jpg

MS soldering tips – Military precision for the highest demands

MS soldering tips stand for Mil-Spec quality: maximum precision, durable materials and maximum durability. They meet the most stringent standards and guarantee reliable results – ideal for aerospace, medical technology and safety-critical electronics manufacturing.

blog/Reinraumschutzklassen_Teaser_Wissen_260x125px_DE+EN_2025.jpg

Cleanroom classes at a glance: Where cleanliness is crucial

Whether in semiconductor production, medical technology or the pharmaceutical industry - controlled conditions are essential. In our article, we show how cleanrooms can be classified according to ISO 14644-1, VDI 2083 and EU GMP, which requirements apply and where which cleanroom classes are used.

Latest posts from our blog

blog/kachel_kennzeichnung_berufs_sicherheitsschuhe_260x125px.png

Marking of safety and occupational footwear

The labelling of occupational and safety footwear in Europe is regulated by EU Directive 89/686/EEC and the standard EN ISO 20345:2011 (for safety footwear) and EN ISO 20347:2012 (for occupational footwear).
These standards set out the minimum requirements for the construction, design and testing of footwear intended for occupational health and safety at work.

blog/kachel_service_bodenverlegung_260x125px.png

Your professional installation service for safe ESD flooring throughout Germany

Secure your sensitive work areas with professional ESD flooring installation – throughout Germany, compliant with standards, and flexible during ongoing operations. Our experienced team at DPV Elektronik guarantees high-quality service: from expert advice to precise installation.

blog/dpv-blog_weller-MS-kachel_260x125px.jpg

MS soldering tips – Military precision for the highest demands

MS soldering tips stand for Mil-Spec quality: maximum precision, durable materials and maximum durability. They meet the most stringent standards and guarantee reliable results – ideal for aerospace, medical technology and safety-critical electronics manufacturing.