Workstation monitor WS Aware
dpvlink 14088
Properties:
- "Big Brother" monitoring function detects users who are not correctly grounded
- Extremely low voltage (25mV CA) for permanent monitoring of voltage and resistance of the twin conductor wrist straps
- Monitoring of grounding parameters according to ANSI 6.1 and ANSI/ESD S20.20
- EMI monitoring of ground connections
- RJ45 port for data transfer to the computer

Wrist monitor
Ground connection: | 1 MOhm per wrist strap connector |
Wrist connections: | 2 x Remote Terminals (1 Operator, 1 visitor) |
Test voltage to the body | 0.025 V (25 mV) |
Body bleeder resistance alarm level: | 10 MOhm default*. |
Body voltage alarm level: | +/-2.5 V default*. |
Ground monitor
Hard ground terminal (tools, machine): | 2 connections |
Dissipative surfaces: | 2 connections |
Alarm for hard grounding*: | 10 Ohm default |
Alarm for dissipative grounding*: | 1 GOhm default |
Imposed voltage | |
Hard connection: | < 0.075 V open circuit |
Dissipative surfaces: | < 0.4 V open circuit |
Power consumption: | < 150 mA |
Dimensions: | 81 mm x 57 mm x 33 mm |
Weight (approx.): | 120 g |
* These parameters are either locally settable in the control panel or through a plant monitoring system. Default values are used if there is no other specification.
Article image
Article description
ESD
Width
Height
Length
Recommended calibration interval
Weight
Price
Compare

81 mm
32 mm
57 mm
12 months bzw. according to test equipment list
140 g

81 mm
32 mm
57 mm
12 months bzw. according to test equipment list
140 g